DC CONTACTOR MAGNETIC LATCHING ZLJM-100C (SU-60)
Beschreibung
DC CONTACTOR MAGNETIC LATCHING RELAY
ZLJM-100C (SU-60)
FEATURES
· 80A Contact Switching capability
· Anwendung: For Electric Control System Of Communication Power Supply,
Engineering Machine,Electro motion Forklift,Motor Car,Train,Watercraft
and UPS etc.
· Certificate: UL, CCC
· ROHS
SPEZIFIKATIONEN
Modell | ZLJM-100C/ | ZLJM100C/B |
Contact Material | Ag-Legierung | |
Contact Rating (at Resistive Load) | 100EIN×60V DC | 100EIN×120V DC |
Contact Voltage Drop | 100A@80mV Max. | |
Isolationswiderstand | Mindest. 100MOh at 500VDC | |
Dielectric Strength (Between Insulated Electric Parts) | 1000VAC 50 Hz/60 Hz (1 minute) | |
Pick up time | max. 30mSec. | |
Drop out time | max. 30mSec. | |
DC–pulse duration | 0.5S~1S | |
Ambient Temperature | -25℃~+60℃ | |
Storage Temperature | -40℃~+65℃ | |
Relative Humidity | +20%~+90% RH | |
Shocking of fixed point | (10~200)Hertz,Acceleration≤3.5g | |
Shocking | (60~100)Ops./min,Acceleration≤4g | |
Mechanical Life Time | 100,000 Operations (no load) | |
Electrical Life Time | 6,000 Operations (at rated load) | |
Auxiliary contact switching capacities (Resistive laden) | 5A /24V DC; 2A/ 48VDC | |
Auxiliary contact switching capacities (Mindest. laden) | 100mA/5V | |
Pollution Level | III | |
Working Duty | Continuous |
COIL DATA
Modell | Coil voltage (v) | Coil Working voltage (v) | Pick-up Stromspannung (v) | Drop-out Stromspannung (v) | Coil Holding Aktuell (EIN) | Coil power dissipation (W) |
ZLJM-80C | 12 |
0.85US~1.1US |
20%~80% |
20%~80% | ≤2.2 |
20~35 |
24 | ≤1.1 | |||||
30 | ≤0.85 | |||||
36 | ≤0.8 | |||||
48 | ≤0.55 | |||||
60 | ≤0.45 | |||||
72 | ≤0.35 | |||||
80 | ≤0.35 | |||||
96 | ≤0.3 | |||||
120 | ≤0.28 |
REMARKS
1. While assemble contactor, tighten torque of nut of terminal screw in main circuit is 4~5N.m.
2. Driving circuit power for coil must be no less than coil power; otherwise, it will reduce cutting capacity of product.
3. Continuous applied voltage should not exceed the maximum permission voltage. Otherwise, abnormal heating of coil will shorten the life of insulating coating.
4. This contactor is non-waterproof, please don’t use in water, solvent, oil and other environment that may contact with the shell or terminal. Otherwise, it may cause abnormal heating due to the burn-in of shell or corrosion, dirty of terminal.
Zusätzliche Information
Herkunftsort: | Zhejiang, China |
---|---|
Markenname: | DY |
Modellnummer: | ZLJM-100C |
Stromart: | Gleichstrom |
Anzahl der Pole: | 2 |
Phase: | 1 |
Main Circuit Rating Voltage: | 12VDC-120VDC |
Main Circuit Rating Current: | 100EIN |
Produktname: | DC-Schütz |
Contactor form: | Magnetic Latching type |
Nennspannung: | 60VDC |
Nennstrom: | 100EIN |
Coil Voltage: | 12,24,30,48,60,72,120,etc |
Zertifikat: | UL,TÜV, ROHS |
Anwendung: | Battery car,Elevator,forklift,Engineering machine,tuk tuk ,etc |
Technical specification: | GB14048.4-2010 |
Original: | Yueqing, Wenzhou |