Beschreibung
Merkmale
Two built in fixing methods: panel/busbar
Very easy to install
Wide inner window,allowing clamping of big cables or bus-bars
Wide range of sizes to accommodate all the existing installation
Primary current form 5A to 5000A
Beschreibung
The DP series split core current transformer has been specially designed to facilitate their installation in new or already existing net works.
They may be installed without opening any cable or bus-bar circuit. The connection of conventional CTs usually requires the interruption of the primary side current to pass cables or bus-bar through the transformer core to connect such cables to the primary terminals.
Spezifikationen
Nennfrequenz | 50/60Hertz |
Rated test voltage | 3Kv AC (1 Mindest) |
Rated short-time thermal current (Ith) | 60Im |
Rated dynamic current (Idyn) | 2.5Ith |
Nennspannung (Um) | 0.72Kv AC |
Continuous overload (Id) | 1.2Im |
Betriebstemperatur | .-10 degree to 50 Grad |
Housing self-extinguishing class | VO |
Safety factor | FS 5 |
Secondary current | 5A/1A |
Standard
IEC60044-1 GB1208-2006
Art | Ratio(EIN) | Burden(VA) | |
Class:0.5 | Class:1.0 | ||
DP-23 | 100/5 | – | 1.5 |
DP-23 | 150/5 | – | 1.5 |
DP-23 | 200/5 | – | 1.5 |
DP-23 | 250/5 | – | 1.5 |
DP-23 | 300/5 | 1.5 | 2.5 |
DP-23 | 400/5 | 2.5 | 3.75 |
DP-58 | 250/5 | – | 1.5 |
DP-58 | 300/5 | – | 2.5 |
DP-58 | 400/5 | 1.5 | 2.5 |
DP-58 | 500/5 | 2.5 | 5 |
DP-58 | 600/5 | 2.5 | 5 |
DP-58 | 750/5 | 2.5 | 5 |
DP-58 | 800/5 | 3.75 | 5 |
DP-58 | 1000/5 | 5 | 10 |
DP-88 | 250/5 | – | 1.5 |
DP-88 | 300/5 | – | 1.5 |
DP-88 | 400/5 | – | 2.5 |
DP-88 | 500/5 | 1.5 | 2.5 |
DP-88 | 600/5 | 1.5 | 2.5 |
DP-88 | 750/5 | 2.5 | 5 |
DP-88 | 800/5 | 3.75 | 5 |
DP-88 | 1000/5 | 7.5 | 7.5 |
DP-812 | 500/5 | – | 2.5 |
DP-812 | 600/5 | – | 2.5 |
DP-812 | 750/5 | 2.5 | 5 |
DP-812 | 800/5 | 2.5 | 5 |
DP-812 | 1000/5 | 3.75 | 7.5 |
DP-812 | 1200/5 | 5 | 10 |
DP-812 | 1250/5 | 5 | 10 |
DP-812 | 1500/5 | 7.5 | 10 |
DP-816 | 1000/5 | 5 | 10 |
DP-816 | 1500/5 | 7.5 | 10 |
DP-816 | 2000/5 | 10 | 15 |
DP-816 | 2500/5 | 15 | 20 |
DP-816 | 3000/5 | 20 | 25 |
DP-816 | 4000/5 | 20 | 25 |
DP-816 | 5000/5 | 20 | 25 |
DP-816 | 6000/5 | 20 | 25 |
DP-820 | 5000/5EIN | 20 | 25 |
DP-820 | 6000/5EIN | 20 | 25 |
DP-820 | 7000/5EIN | 20 | 25 |
DP-820 | 8000/5EIN | 20 | 25 |
DP-820 | 9000/5EIN | 20 | 25 |
DP-820 | 10000/5EIN | 20 | 25 |
Zusätzliche Information
Herkunftsort: | Zhejiang, China |
---|---|
Markenname: | ANA |
Modellnummer: | DP-23, DP-58, DP-88, DP-812, DP-816 |
Verwendungszweck: | Aktuell |
Phase: | Einzel |
Spulenstruktur: | TOROIDAL |
Spulennummer: | AUTOTRANSFORMATOR |
Farbe: | Schwarz |
Feature: | Opening Type |
Zertifikat: | CE, ROHS |
Frequenz: | 50/60Hertz |
Safety Factor: | FS 5 |
Nennspannung: | 0.72KV |
Withstand Voltage: | 3KVAC (1 Mindest) |
Arbeitstemperatur: | -10℃-50℃ |
Name: | DP model split core current transformer |