Outdoor 11lkv 12KV 24lv 33kv High Voltage auto Circuit Recloser
Descripción
Descripción del producto
Especificación
Resumen
Four-faith Smart Power strives to bring our customers the latest technology and competitive pricing and best service for distribut
ion automatic.
The F-OCB series automatic circuit reclosers can use on overhead distribution lines as well as distribution substation applicati
ons for all voltage classes 11kV up to 38kV at 50/60Hz power system. and it’s rated current can reach 1250A.
The F-OCB series automatic circuit reclosers integrates the functions of control, proteccion, measurement, communication, fault de
tection, on-line monitoring of closing or opening.
Four-faith Smart Power strives to bring our customers the latest technology and competitive pricing and best service for distribut
ion automatic.
The F-OCB series automatic circuit reclosers can use on overhead distribution lines as well as distribution substation applicati
ons for all voltage classes 11kV up to 38kV at 50/60Hz power system. and it’s rated current can reach 1250A.
The F-OCB series automatic circuit reclosers integrates the functions of control, proteccion, measurement, communication, fault de
tection, on-line monitoring of closing or opening.
Service environment
1.Air temperature: Maximum temperature: +85℃; Minimum temperature:-45℃
2.Humedad: Monthly average humidity 95%; Daily average humidity 90% .
3.Altitude above sea level: Maximum installation altitude: 2500m or more higher.
4.Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
5.Summer barometric 84.7Kpa(635mmHg) Winter barometric 85.6Kpa(642mmHg) Max wind speed 34m/s
6.Humidity of 13mg and Vapour Pressure 17mm/Hg. No frequent violent shake.
1.Air temperature: Maximum temperature: +85℃; Minimum temperature:-45℃
2.Humedad: Monthly average humidity 95%; Daily average humidity 90% .
3.Altitude above sea level: Maximum installation altitude: 2500m or more higher.
4.Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
5.Summer barometric 84.7Kpa(635mmHg) Winter barometric 85.6Kpa(642mmHg) Max wind speed 34m/s
6.Humidity of 13mg and Vapour Pressure 17mm/Hg. No frequent violent shake.
Offering
With optional classes for installation styles:
Fase única, vacuum recloser and Three phase, vacuum recloser. With optional relay protection curves for user choice: Instantaneo
us over-current protection.
Timing over-current protection.
Negative sequence over-current protection. Directional over-current protection(*).
Over-voltage protection./Under voltage protection. More relay functions can be customized.
With optional choice by locally or remotely.
With optional communication protocols & I/O port for user choice: RS-232 and RS-485 ports supporting.
DNP3.0 communication protocol support(*). Modbus communication protocol is optional(*). CEI 60870-5-101 communication protocol
apoyo.
CEI 60870-5-104 communication protocol support.(*).
The recloser can communicate through GPRS(Or GSM) modem with English or Chinese language (*). With optional functions for user.
Rated currents, System phase current.
Rated voltages, System phase voltage& secondary low voltage power supply voltage. Frecuencia, energía(kWh), reactive power(kV arh),
power factor .
With optional reclosing interval for user pre-program: Reclosing times setting support.
Dead time setting support.
Fase única, vacuum recloser and Three phase, vacuum recloser. With optional relay protection curves for user choice: Instantaneo
us over-current protection.
Timing over-current protection.
Negative sequence over-current protection. Directional over-current protection(*).
Over-voltage protection./Under voltage protection. More relay functions can be customized.
With optional choice by locally or remotely.
With optional communication protocols & I/O port for user choice: RS-232 and RS-485 ports supporting.
DNP3.0 communication protocol support(*). Modbus communication protocol is optional(*). CEI 60870-5-101 communication protocol
apoyo.
CEI 60870-5-104 communication protocol support.(*).
The recloser can communicate through GPRS(Or GSM) modem with English or Chinese language (*). With optional functions for user.
Rated currents, System phase current.
Rated voltages, System phase voltage& secondary low voltage power supply voltage. Frecuencia, energía(kWh), reactive power(kV arh),
power factor .
With optional reclosing interval for user pre-program: Reclosing times setting support.
Dead time setting support.
With events recording function: SOE 1000 operations record.
Fault record and normal operation record.
Nota: (*) mean should customized by manufacturer if needed.
Artículo | Unidad | Data | ||||
Tensión nominal | kV | 11/15 | 27 | 38 | ||
Corriente nominal | A | 400/630/800/1250 | ||||
Frecuencia nominal | Hz | 50/60 | ||||
Rated short circuit breaking current | kA | 12.5/16/20/25 | ||||
Rated short current switching current(peak) | kA | 31.5/40/50/63 | ||||
Tensión soportada de impulso tipo rayo(peak) | kV | 95/110 | 125/165 | 170/200 | ||
Rated peak value withstand current | kA | 31.5/40/50/63 | ||||
4S short time withstand current | kA | 12.5/16/20/25 | ||||
Rated operating circulate | oh-0.5S-CO-2S-CO-5S-CO | |||||
Breaking current frequency under rated short circuit | time | 200 | ||||
Mechanism life | time | 30000 | ||||
Secondary loop 1 min power frequency withstand | kV | 2 |
Información Adicional
Lugar de origen: | fujián, Porcelana |
---|---|
Nombre de la marca: | Four-Faith |
Número de modelo: | F-FTU200 |
Nombre del producto: | auto recloser |
Air temperature: | -45℃-+85℃ |
Humedad: | Monthly average humidity 95%; Daily average humidity 90% |
Altitude above sea level: | 2500m or more higher |
barometric: | Summer barometric 84.7Kpa(635mmHg) Winter barometric 85.6Kpa(642mmHg) |
Corriente nominal: | 400/630/800/1250 A |
Frecuencia nominal: | 50/60 Hz |
Rated operating circulate: | oh-0.5S-CO-2S-CO-5S-CO |
Mechanism life: | 200 time |