Economic Reliable split core transformador
La description
Fonctionnalités
Two built in fixing methods: panel/busbar
Very easy to install
Wide inner window,allowing clamping of big cables or bus-bars
Wide range of sizes to accommodate all the existing installation
Primary current form 5A to 5000A
La description
The DP series split core current transformer has been specially designed to facilitate their installation in new or already existing net works.
They may be installed without opening any cable or bus-bar circuit. The connection of conventional CTs usually requires the interruption of the primary side current to pass cables or bus-bar through the transformer core to connect such cables to the primary terminals.
Caractéristiques
Rated frequency | 50/60hertz |
Rated test voltage | 3Kv AC (1 min) |
Rated short-time thermal current (Ith) | 60Dans |
Rated dynamic current (Idyn) | 2.5Ith |
Tension nominale (Um) | 0.72Kv AC |
Continuous overload (Id) | 1.2Dans |
Température de fonctionnement | .-10 degree to 50 degré |
Housing self-extinguishing class | VO |
Safety factor | FS 5 |
Secondary current | 5A/1A |
Standard
IEC60044-1 GB1208-2006
Taper | Rapport(UN) | Burden(Virginie) | |
Classer:0.5 | Classer:1.0 | ||
DP-23 | 100/5 | – | 1.5 |
DP-23 | 150/5 | – | 1.5 |
DP-23 | 200/5 | – | 1.5 |
DP-23 | 250/5 | – | 1.5 |
DP-23 | 300/5 | 1.5 | 2.5 |
DP-23 | 400/5 | 2.5 | 3.75 |
DP-58 | 250/5 | – | 1.5 |
DP-58 | 300/5 | – | 2.5 |
DP-58 | 400/5 | 1.5 | 2.5 |
DP-58 | 500/5 | 2.5 | 5 |
DP-58 | 600/5 | 2.5 | 5 |
DP-58 | 750/5 | 2.5 | 5 |
DP-58 | 800/5 | 3.75 | 5 |
DP-58 | 1000/5 | 5 | 10 |
DP-88 | 250/5 | – | 1.5 |
DP-88 | 300/5 | – | 1.5 |
DP-88 | 400/5 | – | 2.5 |
DP-88 | 500/5 | 1.5 | 2.5 |
DP-88 | 600/5 | 1.5 | 2.5 |
DP-88 | 750/5 | 2.5 | 5 |
DP-88 | 800/5 | 3.75 | 5 |
DP-88 | 1000/5 | 7.5 | 7.5 |
DP-812 | 500/5 | – | 2.5 |
DP-812 | 600/5 | – | 2.5 |
DP-812 | 750/5 | 2.5 | 5 |
DP-812 | 800/5 | 2.5 | 5 |
DP-812 | 1000/5 | 3.75 | 7.5 |
DP-812 | 1200/5 | 5 | 10 |
DP-812 | 1250/5 | 5 | 10 |
DP-812 | 1500/5 | 7.5 | 10 |
DP-816 | 1000/5 | 5 | 10 |
DP-816 | 1500/5 | 7.5 | 10 |
DP-816 | 2000/5 | 10 | 15 |
DP-816 | 2500/5 | 15 | 20 |
DP-816 | 3000/5 | 20 | 25 |
DP-816 | 4000/5 | 20 | 25 |
DP-816 | 5000/5 | 20 | 25 |
DP-816 | 6000/5 | 20 | 25 |
DP-820 | 5000/5UN | 20 | 25 |
DP-820 | 6000/5UN | 20 | 25 |
DP-820 | 7000/5UN | 20 | 25 |
DP-820 | 8000/5UN | 20 | 25 |
DP-820 | 9000/5UN | 20 | 25 |
DP-820 | 10000/5UN | 20 | 25 |
Informations Complémentaires
Lieu d'origine: | Zhejiang, Chine |
---|---|
Marque: | ANA |
Numéro de modèle: | DP-23, DP-58, DP-88, DP-812, DP-816 |
Usage: | Courant |
Phase: | Seul |
Structure de la bobine: | TOROIDAL |
Numéro de bobine: | TRANSFORMATEUR AUTOMATIQUE |
Couleur: | Le noir |
Caractéristique: | Opening Type |
Certificat: | CE, RSST |
La fréquence: | 50/60hertz |
Safety Factor: | FS 5 |
Tension nominale: | 0.72KV |
Withstand Voltage: | 3KVAC (1 Min) |
Température de fonctionnement: | -10℃-50℃ |
Nom: | DP model split core current transformer |