Vente!
Etco2 Vital Signs De Nursing Monitor With Stand Multiparameter Apnea Breathing Medical Bis Monitor
La description
Etco2 Vital Signs De Nursing Monitor With Stand Multiparameter Apnea Breathing Medical Bis Monitor
Fonctionnalités &Benefits: | ||
1. 12.1” color TFT display, high resolution: 800×600dpi; | ||
2. Separated para board: ECG, NIBP, SpO2 board; | ||
3. Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, la norme configuration includes the navigation knob. | ||
4. Real time S-T segment analysis, and ARR analysis; | ||
5. SpO2 Pitch Tone Variation and Drug Dose Calculation; | ||
6. Parameter waveform and characters color selectable | ||
7. Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic | ||
8. Standby mode for Energy saving and suspend monitoring; | ||
9. 7-lead ECG waveforms display in phase; | ||
10. Capture dynamic waveforms; | ||
11. Built-in rechargeable lithium battery, and battery volume checking, | ||
12. AC power checking | ||
13. Efficient resistance to interference of defibrillator and HF knife; | ||
14. SINNOR F-6 SpO2 technology, VS NELLCOR accuracy; | ||
15. Networking capacity and TCP/IP networking platform enable abundant future upgrade | ||
16. Time delay switch-off function keep the monitor data restart monitor; | ||
17. Complete and flexible mounting solution for transportation and in-patient monitoring | ||
Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR. | ||
Optionnel: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO, | ||
Performance Specifications | ||
Afficher: | 12.1”color TFT | |
Rolling and refreshing waveform display | ||
Résolution: 800×600 | ||
Multi display selectable including: | ||
Large-font display | ||
Trend coexist display | ||
OxyCRG dynamic view display. | ||
Bed-to-bed view display | ||
Trace: | 9 waveforms(7 ECG, 1 SPO2 and 1 RESP) | |
Sweep speed:12.5mm/s,25mm/s,50mm/s | ||
Indicateur: | Power/battery indicator light | |
QRS beep and alarm sound | ||
La batterie: | Rechargeable lead acid cell, 12v/4AH | |
Max.24 hour for charging, 4 hours for continue working | ||
Trend: | Parameter graphic and tabular trends: | |
5s/piece,8 heures; | ||
1min/piece,168 heures(24hour×7days) | ||
5min/piece,1000 heures. | ||
Stockage: | NIBP: 1000 groupes | |
Alarme: 200 groupes | ||
Full disclosure waveforms: 3600S | ||
SD card external storage | ||
Alarme: | User-adjustable High, Medium and Low limits 3-level | |
Audible and visual alarm | ||
Networking: | Connected to central monitoring system | |
TCP/IP netting platform | ||
Recorder: | Construire dans, thermal array | |
Plethysmogram caveform:2 channels | ||
Record mode: manual, on alarm, time-defined | ||
Recording width: 50millimètre | ||
Printing speed: 50mm/s | ||
Recording type: | Frozen waveform record | |
NIBP recall record | ||
Trend table record | ||
Alarm record | ||
Fixed -time record | ||
Standard parameter: | ||
ECG: | ||
Lead mode: | 5 –lead(R,L,F,N,C) | |
Lead selection : | I,II,III,avR,avL,avF,V | |
Waveform: | 3 et 7 channel selectable | |
Gain selection: | 0.5mm/mv,1mm/mv,2mm/mv | |
Sweep speed: | 12.5mm/s;25mm/s;50mm/s | |
Heart rate range: | Adult: 15~300bpm; | |
Neonate/pediatric:15~350bpm | ||
Précision: | +1bpm or +1%,whichecer is greater | |
Résolution: | 1bpm | |
Filtre: | surgery mode:1~20Hz | |
monitor model:0.5~40Hz | ||
Diagnostic mode:0.05~130Hz | ||
Scaling signal: | 1m.v.,+3% | |
protection: | withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation | |
Alarm range: | 15~350bpm | |
S-T segment detecton: | ||
Plage de mesure: | 2.0mV~+2.0mV | |
Alarm Range: | -2.0mV~ +2.0mV | |
Précision: | -0.8mV ~+0.8Mv | |
Erreur: | +0.02Mv | |
Arrhythmia analysis: | OUI | |
SPO2 | ||
Plage de mesure: | 0~100% | |
Résolution: | 1% | |
Précision: | +2%(70-100%);0-69% unspecified | |
Alarm range | 0~100% | |
Pluse Rate range: | 20~300bpm | |
Erreur: | +1bpm or +2%,whichever is greater | |
NIBP | ||
Method: | Digital Automatic oscillometric | |
Mode de fonctionnement : | Manual/Automatic/continuous | |
Auto measurement time: | Adjustable(1~480min) | |
Measurement Unit: | mmHg/Kpa selectable | |
Measurement types: | Systolic, Diastolic, Mean | |
Measurement tange: | ||
Range of Systolic pressure | Adult: 40~270mmHg | |
Pediatric: 40~220mmHg | ||
Neonate: 40~135mmHg | ||
Range of mean pressure: | Adult: 20~235mmHg | |
Pediatric: 20~165mmHg | ||
Neonate: 20~110mmHg | ||
Range of diastolic pressure: | Adult: 10~215mmHg | |
Pediatric: 10~150mmHg | ||
Neonate :10~100mmHg | ||
Over-pressure protection: | Double safety protection | |
Résolution: | 1 mmHg | |
Alarme | Systolic.Diastolic,Mean | |
RESPIRATION | ||
Method: | Thoracic impedance | |
Plage de mesure: | Adult:7~120rpm; Neonate/Pediatric:7~150rpm | |
Apnea alarm: | OUI,10~40s | |
Résolution: | 1tr/min | |
Précision: | +2tr/min | |
TEMPERATURE | ||
Compatible probe: | YSI or CYF +0.1℃ | |
Plage de mesure: | 5~50℃ | |
Résolution : | 0.1℃ | |
Précision: | +0.1℃ | |
Refreshing time: | sur 1 | |
Average measuring time: | <10s | |
FHR | ||
Transducer: | Multi-crystal, Pulsed Doppler | |
Plage de mesure: | 50~210 BPM | |
Working frequency: | 1 MHz | |
Force: | <5mW/cm[] | |
Signal processing: | special DSP system and modern recognization. | |
Résolution: | 1BPM | |
Précision: | ±1BPM | |
Alarm Range: | High: 160,170,180,190 BPM, Low: 100,110,120 BPM | |
FM | ||
Manual button marking, | ||
automatic FM identifying function | ||
TOCO Measuring | ||
Transducer: External pressure transducer | ||
Plage de mesure: 0~100 units | ||
Résolution: 1tr/min | ||
Précision: ±2 rpm | ||
IBP | ||
Canal: 2 channels | ||
Intervalle: -50-300mmHg | ||
Résolution: 1mmHg | ||
Précision: ±4mmHg(±4%) | ||
Unité: mmHg, Kpa | ||
Converter Sensitivity: 5V/V/mmHg | ||
Transducer sites: ART/PA/CVP/LAP/RAP/ICP | ||
EtCO2( Sidertream CO2) | ||
Plage de mesure: 0~99mmHg | ||
Précision: +2mmHg (0~40mmHg) | ||
Sampling Range: 100ml/min | ||
Sampling rate accuracy: 15% | ||
Respiration rate: 0~120rmp | ||
Respiration accuracy: +2rmp (0~70rmp) | ||
+5rmp (>70rmp) | ||
Respiration time: <240msec (10% à 90%) | ||
Delay time: <2s | ||
EtCO2 (mainstreaam CO2) | ||
Method: Infrared Spectrum | ||
Intervalle: 0.0-10% (0~76%) | ||
Résolution: 1mmHg (0.1%) | ||
Précision: <5%(±4.0 mmHg) Or<10%(of Readings) | ||
Recorder: | ||
Construire dans, thermal array | ||
Plethysmogram caveform:2 channels | ||
Record mode: manual, on alarm, time-defined | ||
Recording width: 50millimètre | ||
Printing speed: 50mm/s | ||
Recording type: Frozen waveform record NIBP recall record Trend table record Alarm record Fixed -time record |
Fonctionnalités &Benefits: | ||
1. 12.1” color TFT display, high resolution: 800×600dpi; | ||
2. Separated para board: ECG, NIBP, SpO2 board; | ||
3. Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, la norme configuration includes the navigation knob. | ||
4. Real time S-T segment analysis, and ARR analysis; | ||
5. SpO2 Pitch Tone Variation and Drug Dose Calculation; | ||
6. Parameter waveform and characters color selectable | ||
7. Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic | ||
8. Standby mode for Energy saving and suspend monitoring; | ||
9. 7-lead ECG waveforms display in phase; | ||
10. Capture dynamic waveforms; | ||
11. Built-in rechargeable lithium battery, and battery volume checking, | ||
12. AC power checking | ||
13. Efficient resistance to interference of defibrillator and HF knife; | ||
14. SINNOR F-6 SpO2 technology, VS NELLCOR accuracy; | ||
15. Networking capacity and TCP/IP networking platform enable abundant future upgrade | ||
16. Time delay switch-off function keep the monitor data restart monitor; | ||
17. Complete and flexible mounting solution for transportation and in-patient monitoring | ||
Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR. | ||
Optionnel: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO, | ||
Performance Specifications | ||
Afficher: | 12.1”color TFT | |
Rolling and refreshing waveform display | ||
Résolution: 800×600 | ||
Multi display selectable including: | ||
Large-font display | ||
Trend coexist display | ||
OxyCRG dynamic view display. | ||
Bed-to-bed view display | ||
Trace: | 9 waveforms(7 ECG, 1 SPO2 and 1 RESP) | |
Sweep speed:12.5mm/s,25mm/s,50mm/s | ||
Indicateur: | Power/battery indicator light | |
QRS beep and alarm sound | ||
La batterie: | Rechargeable lead acid cell, 12v/4AH | |
Max.24 hour for charging, 4 hours for continue working | ||
Trend: | Parameter graphic and tabular trends: | |
5s/piece,8 heures; | ||
1min/piece,168 heures(24hour×7days) | ||
5min/piece,1000 heures. | ||
Stockage: | NIBP: 1000 groupes | |
Alarme: 200 groupes | ||
Full disclosure waveforms: 3600S | ||
SD card external storage | ||
Alarme: | User-adjustable High, Medium and Low limits 3-level | |
Audible and visual alarm | ||
Networking: | Connected to central monitoring system | |
TCP/IP netting platform | ||
Recorder: | Construire dans, thermal array | |
Plethysmogram caveform:2 channels | ||
Record mode: manual, on alarm, time-defined | ||
Recording width: 50millimètre | ||
Printing speed: 50mm/s | ||
Recording type: | Frozen waveform record | |
NIBP recall record | ||
Trend table record | ||
Alarm record | ||
Fixed -time record | ||
Standard parameter: | ||
ECG: | ||
Lead mode: | 5 –lead(R,L,F,N,C) | |
Lead selection : | I,II,III,avR,avL,avF,V | |
Waveform: | 3 et 7 channel selectable | |
Gain selection: | 0.5mm/mv,1mm/mv,2mm/mv | |
Sweep speed: | 12.5mm/s;25mm/s;50mm/s | |
Heart rate range: | Adult: 15~300bpm; | |
Neonate/pediatric:15~350bpm | ||
Précision: | +1bpm or +1%,whichecer is greater | |
Résolution: | 1bpm | |
Filtre: | surgery mode:1~20Hz | |
monitor model:0.5~40Hz | ||
Diagnostic mode:0.05~130Hz | ||
Scaling signal: | 1m.v.,+3% | |
protection: | withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation | |
Alarm range: | 15~350bpm | |
S-T segment detecton: | ||
Plage de mesure: | 2.0mV~+2.0mV | |
Alarm Range: | -2.0mV~ +2.0mV | |
Précision: | -0.8mV ~+0.8Mv | |
Erreur: | +0.02Mv | |
Arrhythmia analysis: | OUI | |
SPO2 | ||
Plage de mesure: | 0~100% | |
Résolution: | 1% | |
Précision: | +2%(70-100%);0-69% unspecified | |
Alarm range | 0~100% | |
Pluse Rate range: | 20~300bpm | |
Erreur: | +1bpm or +2%,whichever is greater | |
NIBP | ||
Method: | Digital Automatic oscillometric | |
Mode de fonctionnement : | Manual/Automatic/continuous | |
Auto measurement time: | Adjustable(1~480min) | |
Measurement Unit: | mmHg/Kpa selectable | |
Measurement types: | Systolic, Diastolic, Mean | |
Measurement tange: | ||
Range of Systolic pressure | Adult: 40~270mmHg | |
Pediatric: 40~220mmHg | ||
Neonate: 40~135mmHg | ||
Range of mean pressure: | Adult: 20~235mmHg | |
Pediatric: 20~165mmHg | ||
Neonate: 20~110mmHg | ||
Range of diastolic pressure: | Adult: 10~215mmHg | |
Pediatric: 10~150mmHg | ||
Neonate :10~100mmHg | ||
Over-pressure protection: | Double safety protection | |
Résolution: | 1 mmHg | |
Alarme | Systolic.Diastolic,Mean | |
RESPIRATION | ||
Method: | Thoracic impedance | |
Plage de mesure: | Adult:7~120rpm; Neonate/Pediatric:7~150rpm | |
Apnea alarm: | OUI,10~40s | |
Résolution: | 1tr/min | |
Précision: | +2tr/min | |
TEMPERATURE | ||
Compatible probe: | YSI or CYF +0.1℃ | |
Plage de mesure: | 5~50℃ | |
Résolution : | 0.1℃ | |
Précision: | +0.1℃ | |
Refreshing time: | sur 1 | |
Average measuring time: | <10s | |
FHR | ||
Transducer: | Multi-crystal, Pulsed Doppler | |
Plage de mesure: | 50~210 BPM | |
Working frequency: | 1 MHz | |
Force: | <5mW/cm[] | |
Signal processing: | special DSP system and modern recognization. | |
Résolution: | 1BPM | |
Précision: | ±1BPM | |
Alarm Range: | High: 160,170,180,190 BPM, Low: 100,110,120 BPM | |
FM | ||
Manual button marking, | ||
automatic FM identifying function | ||
TOCO Measuring | ||
Transducer: External pressure transducer | ||
Plage de mesure: 0~100 units | ||
Résolution: 1tr/min | ||
Précision: ±2 rpm | ||
IBP | ||
Canal: 2 channels | ||
Intervalle: -50-300mmHg | ||
Résolution: 1mmHg | ||
Précision: ±4mmHg(±4%) | ||
Unité: mmHg, Kpa | ||
Converter Sensitivity: 5V/V/mmHg | ||
Transducer sites: ART/PA/CVP/LAP/RAP/ICP | ||
EtCO2( Sidertream CO2) | ||
Plage de mesure: 0~99mmHg | ||
Précision: +2mmHg (0~40mmHg) | ||
Sampling Range: 100ml/min | ||
Sampling rate accuracy: 15% | ||
Respiration rate: 0~120rmp | ||
Respiration accuracy: +2rmp (0~70rmp) | ||
+5rmp (>70rmp) | ||
Respiration time: <240msec (10% à 90%) | ||
Delay time: <2s | ||
EtCO2 (mainstreaam CO2) | ||
Method: Infrared Spectrum | ||
Intervalle: 0.0-10% (0~76%) | ||
Résolution: 1mmHg (0.1%) | ||
Précision: <5%(±4.0 mmHg) Or<10%(of Readings) | ||
Recorder: | ||
Construire dans, thermal array | ||
Plethysmogram caveform:2 channels | ||
Record mode: manual, on alarm, time-defined | ||
Recording width: 50millimètre | ||
Printing speed: 50mm/s | ||
Recording type: Frozen waveform record NIBP recall record Trend table record Alarm record Fixed -time record |
Informations Complémentaires
Lieu d'origine: | Chine |
---|---|
Marque: | Sonka |
Numéro de modèle: | SK-J1200 |
Source d'énergie: | Électrique |
garantie: | 1 An |
Service après-vente: | Assistance technique en ligne |
Matériel: | Plastique |
Durée de conservation: | 1années |
Certification de qualité: | ce |
Classement des instruments: | Classe II |
Norme de sécurité: | GB2626-2006 |
Nom du produit: | Patient Monitor |
Taper: | ICU Products |
Une fonction: | SPO2, Resp, Température, Hr, Pr, NIBP, ECG |
Application: | ICU Room |
Mots clés: | Patient Monitoring System |
Caractéristique: | Multi Purpose |
Utilisation: | ICU CCU |
Usage: | First-aid Appliance |
Afficher: | 12.1'' Color TFT Display |
FEO: | OEM Acceptalbe |