Single jet mechanical heat meter with M-BUS or RS-485 or Pulse output
תיאור
תיאור:
YG-RLM (ד) series of heat meters are a new generation of integrated single-flow heat meters developed on the basis of YG-RLM series for the Europe and Russia market. This product uses advanced nonmagnetic technology and has the features of simple structure,
compact size, elegant design, and light weight. It can be used to measure the flows of both heating and cooling systems in living areas.
The temperature range is 4~95℃.
Models and Specifications
דֶגֶם | Qn(m3/h) | אורך(מ"מ) | DN(מ"מ) | Sensor length | לְהַצִיג | Romote | Class |
RLM(ס)-15-0.6 | 0.6 | 110 | 15 | 1.5M | kw/h | M-BUS | 2 |
RLM(ס)-15-0.6 | 0.6 | 110 | 15 | 1.5M | Gcal | RS-485 | 2 |
RLM(ס)-15-1.5 | 1.5 | 110 | 15 | 1.5M | kw/h | M-BUS | 2 |
RLM(ס)-15-1.5 | 1.5 | 110 | 15 | 1.5M | Gcal | RS-485 | 2 |
RLM(ס)-20-2.5 | 2.5 | 130 | 20 | 1.5M | kw/h | M-BUS | 2 |
RLM(ס)-20-2.5 | 2.5 | 130 | 20 | 1.5M | Gcal | RS-485 | 2 |
RLM(ס)-25-2.5 | 2.5 | 160 | 25 | 1.5M | kw/h | M-BUS | 2 |
RLM(ס)-25-2.5 | 2.5 | 160 | 25 | 1.5M | Gcal | RS-485 | 2 |
תכונות:
1. Flow-rate range: 0.6~2.5m3/h.
2. מינימום. temperature difference 3℃
3. Horizontal/vertical installation
4. Embedded and removable installation design to prevent damage during the adjustment period
5. Smart multi-flow design, capable of recording flow rate and volume
6. Advanced nonmagnetic sensing technology
7. High precision design, meeting Class 2 metering requirements of EN1434 and CJ128 standards
8. A lithium battery with service life exceeding six years
9. Optional remote RS485 or M-BUS output, convenient for remote systems
10. Payment settlement date renewable, 18-month data storage
11. 360 degree revolving monitor for easy reading
12. Inclined LCD for optimized viewing
13. Wide measuring range (q s/q i =100:1)
14. Low startup flow rate
15. Capable of measuring both heat and cold energies
16. For use at water inlet end (heat meters for return water end are available at the request of users)
17. PT1000 temperature sensor pair
18. Environment class: א
Main Technical Parameters:
Normal Flow(Qn) | 0.6m3/h | 1.5m3/h | 2.5m3/h |
Flow range(m3/h) | 0.012~1.2 | 0.03~3 | 0.05~5 |
Pressure loss(KPa/Qp) Reference diagram I | 24 | 24 | 24 |
Start flow(L/h) | 3 | 5 | 7 |
מקסימום. לַחַץ(MPa) | 1.6 | ||
Temperature range(℃) | 4~95 |
Pressure Loss Diagram:
Measuring Features:
1.Water pressure: No more than 1Mpa
2.Measuring Class & מקסימום. Tolerance
This product is for Class 2 measurement, and the max tolerance is shown in the curve below:
E=±(3+4Δθmin/Δθ+0.02qp/q)%
Therein, Δθmin means the minimum temperature difference, and Δθ the actual temperature difference.
Dimensional Parameters:
Pipeline Installation Diagram (for Meters Used at Inlet or Outlet for option):
COMPANY PHOTOS
If you are interested in our water meter or have any questions, בבקשה תרגיש בנוח ליצור איתנו קשר!
מידע נוסף
איזור מוצא: | ג'ה-ג'יאנג, חרסינה (יַבֶּשֶׁת) |
---|---|
שם מותג: | ZETON |
מספר דגם: | RLM(ס)-15-25 |
Voltage for RS-485: | 15V to 24V for Russia |
גודל: | DN15mm, DN20mm, DN25mm |
Accuacy: | Class 2 |
Body material: | brass body |
סֵמֶל: | According to customer's label design |
Voltage for M-BUS: | 3.6V |
Measurement: | Kwh, Gcal for choice |
תִקשׁוֹרֶת: | M-BUS, RS-485, Pulse output |
תווית: | English or Russia |
Flow rate: | Qn = 0.6m3/h, Qmax = 1.2m3/h,Qmin = 0.024m3/h |