Vendita!

DC CONTACTOR MAGNETIC LATCHING ZLJM-100C (SU-60)

Categoria:

Descrizione

DC CONTACTOR MAGNETIC LATCHING ZLJM-100C (SU-60)

DC CONTACTOR MAGNETIC LATCHING RELAY

ZLJM-100C (SU-60)

CARATTERISTICHE

· 80A Contact Switching capability

· Applicazione: For Electric Control System Of Communication Power Supply,

Engineering Machine,Electro motion Forklift,Motor Car,Train,Watercraft

and UPS etc.

· Certificate: UL, CCC

· ROHS

SPECIFICATIONS

Modello

ZLJM-100C/

ZLJM100C/B

Materiale di contatto

Ag Alloy

Contact Rating (at Resistive Load)

100UN×60V DC

100UN×120V DC

Contact Voltage Drop

100A@80mV Max.

Insulation Resistance

min. 100MΩ at 500VDC

Rigidità dielettrica

(Between Insulated Electric Parts)

1000VAC 50 Hz/60 Hz (1 minuto)

Pick up time

Massimo. 30mSec.

Drop out time

Massimo. 30mSec.

DC–pulse duration

0.5S~1S

Ambient Temperature

-25~+60

Temperatura di conservazione

-40~+65

Relative Humidity

+20%~+90% RH

Shocking of fixed point

(10~200)Hz,Acceleration3.5g

Shocking

(60~100)Ops./min,Acceleration4g

Mechanical Life Time

100,000 Operations (no load)

Electrical Life Time

6,000 Operations (at rated load)

Auxiliary contact switching capacities (Resistive load)

5A /24V DC; 2A/ 48VDC

Auxiliary contact switching capacities (min. load)

100mA/5V

Pollution Level

III

Working Duty

Continuous

COIL DATA

Modello

Bobina

voltage

(v)

Coil Working voltage

(v)

Pick-up

Voltaggio

(v)

Drop-out

Voltaggio

(v)

Coil Holding

Attuale

(UN)

Potenza della bobina

dissipation

(w)

ZLJM-80C

12

0.85US~1.1US

20%~80%

20%~80%

≤2.2

20~35

24

≤1.1

30

≤0.85

36

≤0.8

48

≤0.55

60

≤0.45

72

≤0.35

80

≤0.35

96

≤0.3

120

≤0.28

REMARKS

1. While assemble contactor, tighten torque of nut of terminal screw in main circuit is 4~5N.m.

2. Driving circuit power for coil must be no less than coil power; otherwise, it will reduce cutting capacity of product.

3. Continuous applied voltage should not exceed the maximum permission voltage. Otherwise, abnormal heating of coil will shorten the life of insulating coating.

4. This contactor is non-waterproof, please don’t use in water, solvent, oil and other environment that may contact with the shell or terminal. Otherwise, it may cause abnormal heating due to the burn-in of shell or corrosion, dirty of terminal.

Informazioni aggiuntive

Luogo d'origine:

Zhejiang, Cina

Marchio:

DY

Numero di modello:

ZLJM-100C

Tipo di elettricità:

DC

Numero di poli:

2

Fase:

1

Tensione nominale del circuito principale:

12VDC-120VDC

Corrente nominale del circuito principale:

100UN

nome del prodotto:

DC Contactor

Contactor form:

Magnetic Latching type

Tensione nominale:

60VCC

Corrente nominale:

100UN

Tensione bobina:

12,24,30,48,60,72,120,eccetera

Certificato:

UL,TUV, ROHS

Applicazione:

Battery car,Elevator,forklift,Engineering machine,tuk tuk ,eccetera

Technical specification:

GB14048.4-2010

Original:

Yueqing, Wenzhou