Vendita!
Etco2 Vital Signs De Nursing Monitor With Stand Multiparameter Apnea Breathing Medical Bis Monitor
Descrizione
Etco2 Vital Signs De Nursing Monitor With Stand Multiparameter Apnea Breathing Medical Bis Monitor
Caratteristiche &Benefits: | ||
1. 12.1” color TFT display, high resolution: 800×600dpi; | ||
2. Separated para board: ECG, NIBP, SpO2 board; | ||
3. Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob. | ||
4. Real time S-T segment analysis, and ARR analysis; | ||
5. SpO2 Pitch Tone Variation and Drug Dose Calculation; | ||
6. Parameter waveform and characters color selectable | ||
7. Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic | ||
8. Standby mode for Energy saving and suspend monitoring; | ||
9. 7-lead ECG waveforms display in phase; | ||
10. Capture dynamic waveforms; | ||
11. Built-in rechargeable lithium battery, and battery volume checking, | ||
12. AC power checking | ||
13. Efficient resistance to interference of defibrillator and HF knife; | ||
14. SINNOR F-6 SpO2 technology, VS NELLCOR accuracy; | ||
15. Networking capacity and TCP/IP networking platform enable abundant future upgrade | ||
16. Time delay switch-off function keep the monitor data restart monitor; | ||
17. Complete and flexible mounting solution for transportation and in-patient monitoring | ||
Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR. | ||
Opzionale: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO, | ||
Performance Specifications | ||
Schermo: | 12.1”color TFT | |
Rolling and refreshing waveform display | ||
Risoluzione: 800×600 | ||
Multi display selectable including: | ||
Large-font display | ||
Trend coexist display | ||
OxyCRG dynamic view display. | ||
Bed-to-bed view display | ||
Trace: | 9 waveforms(7 ECG, 1 SPO2 and 1 RESP) | |
Sweep speed:12.5mm/s,25mm/s,50mm/s | ||
Indicator: | Power/battery indicator light | |
QRS beep and alarm sound | ||
Batteria: | Rechargeable lead acid cell, 12v/4AH | |
Max.24 hour for charging, 4 hours for continue working | ||
Trend: | Parameter graphic and tabular trends: | |
5s/piece,8 ore; | ||
1min/piece,168 ore(24hour×7days) | ||
5min/piece,1000 ore. | ||
Magazzinaggio: | NIBP: 1000 groups | |
Allarme: 200 groups | ||
Full disclosure waveforms: 3600S | ||
SD card external storage | ||
Allarme: | User-adjustable High, Medium and Low limits 3-level | |
Audible and visual alarm | ||
Networking: | Connected to central monitoring system | |
TCP/IP netting platform | ||
Recorder: | Build-in, thermal array | |
Plethysmogram caveform:2 channels | ||
Record mode: manual, on alarm, time-defined | ||
Recording width: 50mm | ||
Printing speed: 50mm/s | ||
Recording type: | Frozen waveform record | |
NIBP recall record | ||
Trend table record | ||
Alarm record | ||
Fixed -time record | ||
Standard parameter: | ||
ECG: | ||
Lead mode: | 5 –lead(R,l,F,N,C) | |
Lead selection : | I,II,III,avR,avL,avF,v | |
Forma d'onda: | 3 e 7 channel selectable | |
Gain selection: | 0.5mm/mv,1mm/mv,2mm/mv | |
Sweep speed: | 12.5mm/s;25mm/s;50mm/s | |
Heart rate range: | Adult: 15~300bpm; | |
Neonate/pediatric:15~350bpm | ||
Precisione: | +1bpm or +1%,whichecer is greater | |
Risoluzione: | 1bpm | |
Filtro: | surgery mode:1~20Hz | |
monitor model:0.5~40Hz | ||
Diagnostic mode:0.05~130Hz | ||
Scaling signal: | 1mv,+3% | |
Protezione: | withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation | |
Alarm range: | 15~350bpm | |
S-T segment detecton: | ||
Measurement range: | 2.0mV~+2.0mV | |
Alarm Range: | -2.0mV~ +2.0mV | |
Precisione: | -0.8mV ~+0.8Mv | |
Error: | +0.02Mv | |
Arrhythmia analysis: | SÌ | |
SPO2 | ||
Measurement range: | 0~100% | |
Risoluzione: | 1% | |
Precisione: | +2%(70-100%);0-69% unspecified | |
Alarm range | 0~100% | |
Pluse Rate range: | 20~300bpm | |
Error: | +1bpm or +2%,whichever is greater | |
NIBP | ||
Method: | Digital Automatic oscillometric | |
Operation mode : | Manual/Automatic/continuous | |
Auto measurement time: | Adjustable(1~480min) | |
Measurement Unit: | mmHg/Kpa selectable | |
Measurement types: | Systolic, Diastolic, Mean | |
Measurement tange: | ||
Range of Systolic pressure | Adult: 40~270mmHg | |
Pediatric: 40~220mmHg | ||
Neonate: 40~135mmHg | ||
Range of mean pressure: | Adult: 20~235mmHg | |
Pediatric: 20~165mmHg | ||
Neonate: 20~110mmHg | ||
Range of diastolic pressure: | Adult: 10~215mmHg | |
Pediatric: 10~150mmHg | ||
Neonate :10~100mmHg | ||
Over-pressure protection: | Double safety protection | |
Risoluzione: | 1 mmHg | |
Allarme | Systolic.Diastolic,Mean | |
RESPIRATION | ||
Method: | Thoracic impedance | |
Measurement range: | Adult:7~120rpm; Neonate/Pediatric:7~150rpm | |
Apnea alarm: | SÌ,10~40s | |
Risoluzione: | 1giri/min | |
Precisione: | +2giri/min | |
TEMPERATURE | ||
Compatible probe: | YSI or CYF +0.1℃ | |
Measurement range: | 5~50℃ | |
Risoluzione : | 0.1℃ | |
Precisione: | +0.1℃ | |
Refreshing time: | about 1 | |
Average measuring time: | <10S | |
FHR | ||
Transducer: | Multi-crystal, Pulsed Doppler | |
Measurement range: | 50~210 BPM | |
Working frequency: | 1 MHz | |
Forza: | <5mW/cm[] | |
Signal processing: | special DSP system and modern recognization. | |
Risoluzione: | 1BPM | |
Precisione: | ±1BPM | |
Alarm Range: | Alto: 160,170,180,190 BPM, Low: 100,110,120 BPM | |
FM | ||
Manual button marking, | ||
automatic FM identifying function | ||
TOCO Measuring | ||
Transducer: External pressure transducer | ||
Measurement range: 0~100 units | ||
Risoluzione: 1giri/min | ||
Precisione: ±2 rpm | ||
IBP | ||
Canale: 2 channels | ||
Allineare: -50-300mmHg | ||
Risoluzione: 1mmHg | ||
Precisione: ±4mmHg(±4%) | ||
Unit: mmHg, Kpa | ||
Converter Sensitivity: 5V/V/mmHg | ||
Transducer sites: ART/PA/CVP/LAP/RAP/ICP | ||
EtCO2( Sidertream CO2) | ||
Measurement range: 0~99mmHg | ||
Precisione: +2mmHg (0~40mmHg) | ||
Sampling Range: 100ml/min | ||
Sampling rate accuracy: 15% | ||
Respiration rate: 0~120rmp | ||
Respiration accuracy: +2rmp (0~70rmp) | ||
+5rmp (>70rmp) | ||
Respiration time: <240msec (10% a 90%) | ||
Delay time: <2S | ||
EtCO2 (mainstreaam CO2) | ||
Method: Infrared Spectrum | ||
Allineare: 0.0-10% (0~76%) | ||
Risoluzione: 1mmHg (0.1%) | ||
Precisione: <5%(±4.0 mmHg) Or<10%(of Readings) | ||
Recorder: | ||
Build-in, thermal array | ||
Plethysmogram caveform:2 channels | ||
Record mode: manual, on alarm, time-defined | ||
Recording width: 50mm | ||
Printing speed: 50mm/s | ||
Recording type: Frozen waveform record NIBP recall record Trend table record Alarm record Fixed -time record |
Caratteristiche &Benefits: | ||
1. 12.1” color TFT display, high resolution: 800×600dpi; | ||
2. Separated para board: ECG, NIBP, SpO2 board; | ||
3. Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob. | ||
4. Real time S-T segment analysis, and ARR analysis; | ||
5. SpO2 Pitch Tone Variation and Drug Dose Calculation; | ||
6. Parameter waveform and characters color selectable | ||
7. Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic | ||
8. Standby mode for Energy saving and suspend monitoring; | ||
9. 7-lead ECG waveforms display in phase; | ||
10. Capture dynamic waveforms; | ||
11. Built-in rechargeable lithium battery, and battery volume checking, | ||
12. AC power checking | ||
13. Efficient resistance to interference of defibrillator and HF knife; | ||
14. SINNOR F-6 SpO2 technology, VS NELLCOR accuracy; | ||
15. Networking capacity and TCP/IP networking platform enable abundant future upgrade | ||
16. Time delay switch-off function keep the monitor data restart monitor; | ||
17. Complete and flexible mounting solution for transportation and in-patient monitoring | ||
Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR. | ||
Opzionale: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO, | ||
Performance Specifications | ||
Schermo: | 12.1”color TFT | |
Rolling and refreshing waveform display | ||
Risoluzione: 800×600 | ||
Multi display selectable including: | ||
Large-font display | ||
Trend coexist display | ||
OxyCRG dynamic view display. | ||
Bed-to-bed view display | ||
Trace: | 9 waveforms(7 ECG, 1 SPO2 and 1 RESP) | |
Sweep speed:12.5mm/s,25mm/s,50mm/s | ||
Indicator: | Power/battery indicator light | |
QRS beep and alarm sound | ||
Batteria: | Rechargeable lead acid cell, 12v/4AH | |
Max.24 hour for charging, 4 hours for continue working | ||
Trend: | Parameter graphic and tabular trends: | |
5s/piece,8 ore; | ||
1min/piece,168 ore(24hour×7days) | ||
5min/piece,1000 ore. | ||
Magazzinaggio: | NIBP: 1000 groups | |
Allarme: 200 groups | ||
Full disclosure waveforms: 3600S | ||
SD card external storage | ||
Allarme: | User-adjustable High, Medium and Low limits 3-level | |
Audible and visual alarm | ||
Networking: | Connected to central monitoring system | |
TCP/IP netting platform | ||
Recorder: | Build-in, thermal array | |
Plethysmogram caveform:2 channels | ||
Record mode: manual, on alarm, time-defined | ||
Recording width: 50mm | ||
Printing speed: 50mm/s | ||
Recording type: | Frozen waveform record | |
NIBP recall record | ||
Trend table record | ||
Alarm record | ||
Fixed -time record | ||
Standard parameter: | ||
ECG: | ||
Lead mode: | 5 –lead(R,l,F,N,C) | |
Lead selection : | I,II,III,avR,avL,avF,v | |
Forma d'onda: | 3 e 7 channel selectable | |
Gain selection: | 0.5mm/mv,1mm/mv,2mm/mv | |
Sweep speed: | 12.5mm/s;25mm/s;50mm/s | |
Heart rate range: | Adult: 15~300bpm; | |
Neonate/pediatric:15~350bpm | ||
Precisione: | +1bpm or +1%,whichecer is greater | |
Risoluzione: | 1bpm | |
Filtro: | surgery mode:1~20Hz | |
monitor model:0.5~40Hz | ||
Diagnostic mode:0.05~130Hz | ||
Scaling signal: | 1mv,+3% | |
Protezione: | withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation | |
Alarm range: | 15~350bpm | |
S-T segment detecton: | ||
Measurement range: | 2.0mV~+2.0mV | |
Alarm Range: | -2.0mV~ +2.0mV | |
Precisione: | -0.8mV ~+0.8Mv | |
Error: | +0.02Mv | |
Arrhythmia analysis: | SÌ | |
SPO2 | ||
Measurement range: | 0~100% | |
Risoluzione: | 1% | |
Precisione: | +2%(70-100%);0-69% unspecified | |
Alarm range | 0~100% | |
Pluse Rate range: | 20~300bpm | |
Error: | +1bpm or +2%,whichever is greater | |
NIBP | ||
Method: | Digital Automatic oscillometric | |
Operation mode : | Manual/Automatic/continuous | |
Auto measurement time: | Adjustable(1~480min) | |
Measurement Unit: | mmHg/Kpa selectable | |
Measurement types: | Systolic, Diastolic, Mean | |
Measurement tange: | ||
Range of Systolic pressure | Adult: 40~270mmHg | |
Pediatric: 40~220mmHg | ||
Neonate: 40~135mmHg | ||
Range of mean pressure: | Adult: 20~235mmHg | |
Pediatric: 20~165mmHg | ||
Neonate: 20~110mmHg | ||
Range of diastolic pressure: | Adult: 10~215mmHg | |
Pediatric: 10~150mmHg | ||
Neonate :10~100mmHg | ||
Over-pressure protection: | Double safety protection | |
Risoluzione: | 1 mmHg | |
Allarme | Systolic.Diastolic,Mean | |
RESPIRATION | ||
Method: | Thoracic impedance | |
Measurement range: | Adult:7~120rpm; Neonate/Pediatric:7~150rpm | |
Apnea alarm: | SÌ,10~40s | |
Risoluzione: | 1giri/min | |
Precisione: | +2giri/min | |
TEMPERATURE | ||
Compatible probe: | YSI or CYF +0.1℃ | |
Measurement range: | 5~50℃ | |
Risoluzione : | 0.1℃ | |
Precisione: | +0.1℃ | |
Refreshing time: | about 1 | |
Average measuring time: | <10S | |
FHR | ||
Transducer: | Multi-crystal, Pulsed Doppler | |
Measurement range: | 50~210 BPM | |
Working frequency: | 1 MHz | |
Forza: | <5mW/cm[] | |
Signal processing: | special DSP system and modern recognization. | |
Risoluzione: | 1BPM | |
Precisione: | ±1BPM | |
Alarm Range: | Alto: 160,170,180,190 BPM, Low: 100,110,120 BPM | |
FM | ||
Manual button marking, | ||
automatic FM identifying function | ||
TOCO Measuring | ||
Transducer: External pressure transducer | ||
Measurement range: 0~100 units | ||
Risoluzione: 1giri/min | ||
Precisione: ±2 rpm | ||
IBP | ||
Canale: 2 channels | ||
Allineare: -50-300mmHg | ||
Risoluzione: 1mmHg | ||
Precisione: ±4mmHg(±4%) | ||
Unit: mmHg, Kpa | ||
Converter Sensitivity: 5V/V/mmHg | ||
Transducer sites: ART/PA/CVP/LAP/RAP/ICP | ||
EtCO2( Sidertream CO2) | ||
Measurement range: 0~99mmHg | ||
Precisione: +2mmHg (0~40mmHg) | ||
Sampling Range: 100ml/min | ||
Sampling rate accuracy: 15% | ||
Respiration rate: 0~120rmp | ||
Respiration accuracy: +2rmp (0~70rmp) | ||
+5rmp (>70rmp) | ||
Respiration time: <240msec (10% a 90%) | ||
Delay time: <2S | ||
EtCO2 (mainstreaam CO2) | ||
Method: Infrared Spectrum | ||
Allineare: 0.0-10% (0~76%) | ||
Risoluzione: 1mmHg (0.1%) | ||
Precisione: <5%(±4.0 mmHg) Or<10%(of Readings) | ||
Recorder: | ||
Build-in, thermal array | ||
Plethysmogram caveform:2 channels | ||
Record mode: manual, on alarm, time-defined | ||
Recording width: 50mm | ||
Printing speed: 50mm/s | ||
Recording type: Frozen waveform record NIBP recall record Trend table record Alarm record Fixed -time record |
Informazioni aggiuntive
Luogo d'origine: | Cina |
---|---|
Marchio: | Sonka |
Numero di modello: | SK-J1200 |
Fonte di potere: | Elettrico |
Garanzia: | 1 Anno |
Servizio post vendita: | Supporto tecnico in linea |
Materiale: | plastica |
Data di scadenza: | 1anni |
Certificazione di qualità: | ce |
Classificazione degli strumenti: | Classe II |
Norma di sicurezza: | GB2626-2006 |
Nome del prodotto: | Patient Monitor |
Tipo: | ICU Products |
Funzione: | SPO2, Resp, Temp, Hr, Pr, NIBP, ECG |
Applicazione: | ICU Room |
Parole chiave: | Patient Monitoring System |
Caratteristica: | Multi Purpose |
Uso: | ICU CCU |
Utilizzo: | First-aid Appliance |
Schermo: | 12.1'' Color TFT Display |
OEM: | OEM Acceptalbe |