Vendita!
Industrial power factor correction unit
Descrizione
Descrizione del prodotto
Nome del prodotto | Industrial power factor correction unit | |||
Working principle | Industrial power factor correction unit is suitable for low power factor electrical system with or without harmonics. This unit is a specially designed system with three configuration options. | |||
Modello numero. | Rated Capacity (kvar) | Dimensione (mm) | ||
Larghezza | Depth | Altezza | ||
SLVC-60/X | 60 | 600 | 600 | 2200 |
SLVC-90/X | 90 | 600 | 600 | 2200 |
SLVC-100/X | 100 | 600 | 600 | 2200 |
SLVC-120/X | 120 | 600 | 600 | 2200 |
SLVC-150/X | 150 | 800 | 600 | 2200 |
SLVC-180/X | 180 | 800 | 800 | 2200 |
SLVC-210/X | 210 | 800 | 800 | 2200 |
SLVC-240/X | 240 | 1000 | 800 | 2200 |
SLVC-270/X | 270 | 1000 | 800 | 2200 |
SLVC-300/X | 300 | 1000 | 800 | 2200 |
SLVC-330/X | 330 | 1200 | 1000 | 2200 |
SLVC-360/X | 360 | 1200 | 1000 | 2200 |
Nota: The size in this table is for the configuration with only reactive power compensation application. | ||||
Caratteristiche | 1. Three configuration options: only reactive power compensation application, reactive power compensation with harmonic filter application, only harmonic filter application. | |||
2. Automatic switching capability, and automatically computer and analyze electrical parameters, such as voltage, current, active power, reactive power, power factor. | ||||
3. Can be normally tuned to the 5th, 7th, 11th, 13th harmonics, efficiency is more than 75%. | ||||
4. Offer quick responding, the fasted time can be less than 20ms. | ||||
5. Reliable and safe structure, facile da installare. | ||||
Service condition | 1. Temperatura ambiente: -10℃ ~ +40℃. | |||
2. Umidità relativa: Meno di 85%, non-condensation. | ||||
3. Altitude: Less than 2000m. (more than 2000m should be with special design.) | ||||
4. Installation site: Indoor service. Vertical inclination shall be less than 5 livello. No fire hazard, explossion risk, conductive dust, corrosive gas and strong vibration exist. | ||||
Ordering Instructions | Please providing following information when you place the order: | |||
1. Harmonics will affect the performance of the unit. If the electrical system has harmonics, please give us the details of harmonic frequencies. | ||||
2. Confirm natural power factor and target power factor. | ||||
3. Any special requirements, such as outdoor installation, please consult with our company. | ||||
4. This low voltage power factor correction unit is working with switchgear, if you don’t have switchgear, you can order the unit together with switchgear from us. |
Profilo Aziendale
Processo di servizio
Customers Visiting
Certificati
Garanzia commerciale
Informazioni aggiuntive
Luogo d'origine: | Hubei, Cina |
---|---|
Marchio: | Zhongsheng |
Numero di modello: | SLVC |
nome del prodotto: | Industrial power factor correction unit |