Uitverkoop!

DC CONTACTOR MAGNETIC LATCHING ZLJM-100C (SU-60)

Categorie:

Beschrijving

DC CONTACTOR MAGNETIC LATCHING ZLJM-100C (SU-60)

DC CONTACTOR MAGNETIC LATCHING RELAY

ZLJM-100C (SU-60)

KENMERKEN

· 80A Contact Switching capability

· Sollicitatie: For Electric Control System Of Communication Power Supply,

Engineering Machine,Electro motion Forklift,Motor Car,Trein,Watercraft

and UPS etc.

· Certificate: de, CCC

· ROHS

SPECIFICATIES

Model

ZLJM-100C/

ZLJM100C/B

Contact Material

Ag-legering

Contact Rating (at Resistive Load)

100EEN×60V gelijkstroom

100EEN×120V gelijkstroom

Contact Voltage Drop

100A@80mV Max.

Insulation Resistance

min. 100MOh at 500VDC

Dielectric Strength

(Between Insulated Electric Parts)

1000VAC 50 Hz/60 Hz (1 minute)

Pick up time

Max. 30mSec.

Drop out time

Max. 30mSec.

DC–pulse duration

0.5S~1S

Ambient Temperature

-25~+60

Bewaar temperatuur

-40~+65

Relative Humidity

+20%~+90% RV

Shocking of fixed point

(10~200)Hz,Acceleration3.5g

Shocking

(60~100)Ops./min,Acceleration4g

Mechanical Life Time

100,000 Operations (no load)

Electrical Life Time

6,000 Operations (at rated load)

Auxiliary contact switching capacities (Resistive load)

5A /24V DC; 2A/ 48VDC

Auxiliary contact switching capacities (min. load)

100mA/5V

Pollution Level

III

Working Duty

Continuous

COIL DATA

Model

Spoel

voltage

(V)

Coil Working voltage

(V)

Pick-up

Spanning

(V)

Drop-out

Spanning

(V)

Coil Holding

Huidig

(EEN)

Coil power

dissipation

(W)

ZLJM-80C

12

0.85US~1.1US

20%~80%

20%~80%

≤2.2

20~35

24

≤1.1

30

≤0.85

36

≤0.8

48

≤0.55

60

≤0.45

72

≤0.35

80

≤0.35

96

≤0.3

120

≤0.28

REMARKS

1. While assemble contactor, tighten torque of nut of terminal screw in main circuit is 4~5N.m.

2. Driving circuit power for coil must be no less than coil power; otherwise, it will reduce cutting capacity of product.

3. Continuous applied voltage should not exceed the maximum permission voltage. Otherwise, abnormal heating of coil will shorten the life of insulating coating.

4. This contactor is non-waterproof, please don’t use in water, solvent, oil and other environment that may contact with the shell or terminal. Otherwise, it may cause abnormal heating due to the burn-in of shell or corrosion, dirty of terminal.

Extra informatie

plaats van herkomst:

Zhejiang, China

Merknaam:

DY

Modelnummer:

ZLJM-100C

Electricity Type:

gelijkstroom

Number of Pole:

2

Fase:

1

Main Circuit Rating Voltage:

12VDC-120VDC

Main Circuit Rating Current:

100EEN

productnaam:

DC Contactor

Contactor form:

Magnetic Latching type

Nominale spanning:

60VDC

Rated Current:

100EEN

Coil Voltage:

12,24,30,48,60,72,120,enz

Certificaat:

de,TUV, ROHS

Sollicitatie:

Battery car,Elevator,forklift,Engineering machine,tuk tuk ,enz

Technical specification:

GB14048.4-2010

Origineel:

Yueqing, Wenzhou