Oferta!![](https://sc01.alicdn.com/kf/H1dbdf07d5cd5465cad9a22f901162d48Z.jpg)
![](https://sc01.alicdn.com/kf/Haccfc52e79bf48b4a99c1f1a38dba7c9h.jpg)
![](https://sc01.alicdn.com/kf/Had848b7c0d5c47a489bbcd7186508359B.jpg)
![](https://sc01.alicdn.com/kf/Hbef7402b06a6443f8f03e19be0665c5dG.jpg)
![](https://sc01.alicdn.com/kf/H8c93ce4f631c49b2aab51209ac68a0c5N.jpg)
![](https://sc02.alicdn.com/kf/H8587fc688b7c4f47b6e4fc0701577afcp.jpg)
![](http://sc01.alicdn.com/kf/H401ea3303b2448aa9b945e1fe64f1eb94/231921809/H401ea3303b2448aa9b945e1fe64f1eb94.png)
![](http://sc01.alicdn.com/kf/Hb4a51bdcb38c414c906106571c1d6704c/231921809/Hb4a51bdcb38c414c906106571c1d6704c.png)
![](http://sc01.alicdn.com/kf/H7418d750af7b46ae867be707d8e38338T/231921809/H7418d750af7b46ae867be707d8e38338T.png)
![](http://sc02.alicdn.com/kf/Ha4ad31eff1434d17b6efba736eae6b3c0/231921809/Ha4ad31eff1434d17b6efba736eae6b3c0.png)
![](http://sc01.alicdn.com/kf/He65b7598356c4563aaec32540a81dfa9A/231921809/He65b7598356c4563aaec32540a81dfa9A.png)
Outdoor 11lkv 12KV 24lv 33kv High Voltage auto Circuit Recloser
Descrição
Descrição do produto
![](http://u.alicdn.com/js/5v/esite/img/img-placeholder.png)
![](http://u.alicdn.com/js/5v/esite/img/img-placeholder.png)
![](http://u.alicdn.com/js/5v/esite/img/img-placeholder.png)
![](http://u.alicdn.com/js/5v/esite/img/img-placeholder.png)
![](http://u.alicdn.com/js/5v/esite/img/img-placeholder.png)
![](http://u.alicdn.com/js/5v/esite/img/img-placeholder.png)
Especificação
Summary
Four-faith Smart Power strives to bring our customers the latest technology and competitive pricing and best service for distribut
ion automatic.
The F-OCB series automatic circuit reclosers can use on overhead distribution lines as well as distribution substation applicati
ons for all voltage classes 11kV up to 38kV at 50/60Hz power system. and it’s rated current can reach 1250A.
The F-OCB series automatic circuit reclosers integrates the functions of control, protection, measurement, communication, fault de
tection, on-line monitoring of closing or opening.
Four-faith Smart Power strives to bring our customers the latest technology and competitive pricing and best service for distribut
ion automatic.
The F-OCB series automatic circuit reclosers can use on overhead distribution lines as well as distribution substation applicati
ons for all voltage classes 11kV up to 38kV at 50/60Hz power system. and it’s rated current can reach 1250A.
The F-OCB series automatic circuit reclosers integrates the functions of control, protection, measurement, communication, fault de
tection, on-line monitoring of closing or opening.
Service environment
1.Air temperature: Maximum temperature: +85℃; Minimum temperature:-45℃
2.Umidade: Monthly average humidity 95%; Daily average humidity 90% .
3.Altitude above sea level: Maximum installation altitude: 2500m or more higher.
4.Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
5.Summer barometric 84.7Kpa(635mmHg) Winter barometric 85.6Kpa(642mmHg) Max wind speed 34m/s
6.Humidity of 13mg and Vapour Pressure 17mm/Hg. No frequent violent shake.
1.Air temperature: Maximum temperature: +85℃; Minimum temperature:-45℃
2.Umidade: Monthly average humidity 95%; Daily average humidity 90% .
3.Altitude above sea level: Maximum installation altitude: 2500m or more higher.
4.Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
5.Summer barometric 84.7Kpa(635mmHg) Winter barometric 85.6Kpa(642mmHg) Max wind speed 34m/s
6.Humidity of 13mg and Vapour Pressure 17mm/Hg. No frequent violent shake.
![](http://u.alicdn.com/js/5v/esite/img/img-placeholder.png)
Offering
With optional classes for installation styles:
Single phase, vacuum recloser and Three phase, vacuum recloser. With optional relay protection curves for user choice: Instantaneo
us over-current protection.
Timing over-current protection.
Negative sequence over-current protection. Directional over-current protection(*).
Over-voltage protection./Under voltage protection. More relay functions can be customized.
With optional choice by locally or remotely.
With optional communication protocols & I/O port for user choice: RS-232 and RS-485 ports supporting.
DNP3.0 communication protocol support(*). Modbus communication protocol is optional(*). IEC 60870-5-101 communication protocol
support.
IEC 60870-5-104 communication protocol support.(*).
The recloser can communicate through GPRS(Or GSM) modem with English or Chinese language (*). With optional functions for user.
Rated currents, System phase current.
Rated voltages, System phase voltage& secondary low voltage power supply voltage. Frequência, potência(kWh), reactive power(kV arh),
power factor .
With optional reclosing interval for user pre-program: Reclosing times setting support.
Dead time setting support.
Single phase, vacuum recloser and Three phase, vacuum recloser. With optional relay protection curves for user choice: Instantaneo
us over-current protection.
Timing over-current protection.
Negative sequence over-current protection. Directional over-current protection(*).
Over-voltage protection./Under voltage protection. More relay functions can be customized.
With optional choice by locally or remotely.
With optional communication protocols & I/O port for user choice: RS-232 and RS-485 ports supporting.
DNP3.0 communication protocol support(*). Modbus communication protocol is optional(*). IEC 60870-5-101 communication protocol
support.
IEC 60870-5-104 communication protocol support.(*).
The recloser can communicate through GPRS(Or GSM) modem with English or Chinese language (*). With optional functions for user.
Rated currents, System phase current.
Rated voltages, System phase voltage& secondary low voltage power supply voltage. Frequência, potência(kWh), reactive power(kV arh),
power factor .
With optional reclosing interval for user pre-program: Reclosing times setting support.
Dead time setting support.
With events recording function: SOE 1000 operations record.
Fault record and normal operation record.
Observação: (*) mean should customized by manufacturer if needed.
Item | Unidade | Data | ||||
Tensão nominal | kV | 11/15 | 27 | 38 | ||
Rated current | UMA | 400/630/800/1250 | ||||
Rated frequency | Hz | 50/60 | ||||
Rated short circuit breaking current | kA | 12.5/16/20/25 | ||||
Rated short current switching current(peak) | kA | 31.5/40/50/63 | ||||
Lightning impulse withstand voltage(peak) | kV | 95/110 | 125/165 | 170/200 | ||
Rated peak value withstand current | kA | 31.5/40/50/63 | ||||
4S short time withstand current | kA | 12.5/16/20/25 | ||||
Rated operating circulate | O-0.5S-CO-2S-CO-5S-CO | |||||
Breaking current frequency under rated short circuit | time | 200 | ||||
Mechanism life | time | 30000 | ||||
Secondary loop 1 min power frequency withstand | kV | 2 |
![](http://u.alicdn.com/js/5v/esite/img/img-placeholder.png)
![](http://u.alicdn.com/js/5v/esite/img/img-placeholder.png)
![](http://u.alicdn.com/js/5v/esite/img/img-placeholder.png)
![](http://u.alicdn.com/js/5v/esite/img/img-placeholder.png)
Informação adicional
Lugar de origem: | Fujian, China |
---|---|
Marca: | Four-Faith |
Número do modelo: | F-FTU200 |
Nome do Produto: | auto recloser |
Air temperature: | -45℃-+85℃ |
Umidade: | Monthly average humidity 95%; Daily average humidity 90% |
Altitude above sea level: | 2500m or more higher |
barometric: | Summer barometric 84.7Kpa(635mmHg) Winter barometric 85.6Kpa(642mmHg) |
Rated current: | 400/630/800/1250 UMA |
Rated frequency: | 50/60 Hz |
Rated operating circulate: | O-0.5S-CO-2S-CO-5S-CO |
Mechanism life: | 200 time |