Verkauf!
THR-IP100 Medical syringe infusion pump
Beschreibung
THR-IP100 Auto Caliration Infusion Pump
Material: | ABS-Kunststoff,Fire-proof |
Abmessungen | 135L*120W*245H mm |
Gewicht: | 2kg |
Besondere Merkmale | |
Precise infusion rate control | ml/h and d/min Switch Display Interface |
Self-diagnosis, infusion pipe installation ,pressure setting,rate setting. | English LCD interface |
KVO function starts once infusion completed. | Night Mode |
Intellectualized drop detector | Hard based Free-flow protection |
Alarm Function Conditions: | |
Infusion complete | Occlusion |
Low battery | Installation error |
Air-on-line | Abnormal rate |
Door open | Operational error |
Screen Display Context | |
Battery charge indicator | Occlusion value: Hoch,Middle and low |
Accumulated Value | Infusion complete |
AC power indicator | Power capacity |
Preset Infusion Value | Infusion speed |
Fast infusion rate | Infusion status |
Alarm type | |
Spezifikation | |
Pump Mechanism: | Peristalsis Mechanism |
Work Mode: | -Continuous working mode |
-Control ModeDrop | |
-Detector Mode | |
Rate Range: | Preset flow rate range: 1-250d/min or 1-1000ml/h. |
( 1d/min or 1ml/h increment) | |
Preset Volume Limit: | 5-9999 ml |
Accumulated Volume: | 0-9999 ml |
Genauigkeit: | ±5% |
KVO Rate(Keep vein open): | 1ml/Std |
Occlusion Value Levels: | Adjustable from High, Middle and low level |
AC Power Supply: | AC 85–264v, 50/60 Hertz |
Battery Type: | DC12V,1800mA/h NI-MH rechargeable battery |
Batterie : | Can use for more than 3 hours after fully recharge(run at middle rate) |
Battery Recharge: | When connect to AC power, it automatically Recharge and use about 15 hours to fully recharge |
Consumption: | <28VA |
Fuse: | F 0.8A H/250V |
Security Level: | Class 2,class BF, internal battery, water-proof |
Operation environment : | Environment temperature +5°C+40° |
Atmospheric pressure:86-106kPa | |
Relative Luftfeuchtigkeit:20%~90% | |
OR | |
Umfeld :Environment temperature -22°C-55°C | |
Atmospheric pressure:50~106kPa | |
Relative Luftfeuchtigkeit:90% | |
Electrical Safety: | In accord with the stipulation of EC 60601-1:1998And EN 60601-1 |
Merkmale: | |
Hard based free-flow protection: | When the door open ,it effectively prevents any free-flow .Prevent any danger to the patients. |
Drop detector: | |
It’s used to calculate the drop infused for the patients, Meanwhile it automatically adjust the accuracy by itself. According to the current infusion set. One of another, the detector can also detect the abnormal flow rate and sends this information to the CPU, The CPU sends instruction to control the peristalsis pieces, accordingly make the accurate infusion come true. | |
Night mode: | |
At night, in order to ensure the patients have a good rest, this pump has the silence function and screen-protection mode. |
Verpackung & Versand
Firmeninformation
Unsere Leistungen
Zusätzliche Information
Art: | Infusion Pump with Auto Caliration |
---|---|
Markenname: | THR |
Modellnummer: | THR-IP100 |
Herkunftsort: | Jiangsu, China |
Instrumentenklassifizierung: | Klasse I |
Garantie: | 1 Jahr |
Service nach dem Verkauf: | Technischer Online-Support |
Produktname: | Caliration Infusion Pump |
AC power supply: | AC 100 to 240V±10%,50/60Hz; |
MOQ: | 1 unit |
Zertifikat: | CE ISO |
Erstausrüster: | Verfügbar |