Πώληση!
THR-IP100 Medical syringe infusion pump
Περιγραφή
THR-IP100 Auto Caliration Infusion Pump
Υλικό: | ABS Plastic,Fire-proof |
Διάσταση | 135L*120W*245H mm |
Βάρος: | 2κιλό |
Special Features | |
Precise infusion rate control | ml/h and d/min Switch Display Interface |
Self-diagnosis, infusion pipe installation ,pressure setting,rate setting. | English LCD interface |
KVO function starts once infusion completed. | Night Mode |
Intellectualized drop detector | Hard based Free-flow protection |
Alarm Function Conditions: | |
Infusion complete | Occlusion |
Low battery | Installation error |
Air-on-line | Abnormal rate |
Door open | Operational error |
Screen Display Context | |
Battery charge indicator | Occlusion value: High,Middle and low |
Accumulated Value | Infusion complete |
AC power indicator | Power capacity |
Preset Infusion Value | Infusion speed |
Fast infusion rate | Infusion status |
Alarm type | |
Προσδιορισμός | |
Pump Mechanism: | Peristalsis Mechanism |
Work Mode: | -Continuous working mode |
-Control ModeDrop | |
-Detector Mode | |
Rate Range: | Preset flow rate range: 1-250d/min or 1-1000ml/h. |
( 1d/min or 1ml/h increment) | |
Preset Volume Limit: | 5-9999 ml |
Accumulated Volume: | 0-9999 ml |
Ακρίβεια: | ±5% |
KVO Rate(Keep vein open): | 1ml/h |
Occlusion Value Levels: | Adjustable from High, Middle and low level |
AC Power Supply: | AC 85–264V, 50/60 Hz |
Τύπος Μπαταρίας: | DC12V,1800mA/h NI-MH rechargeable battery |
Μπαταρία : | Can use for more than 3 hours after fully recharge(run at middle rate) |
Battery Recharge: | When connect to AC power, it automatically Recharge and use about 15 hours to fully recharge |
Consumption: | <28VA |
Ασφάλεια ηλεκτρική: | F 0.8A H/250V |
Security Level: | Class 2,class BF, internal battery, water-proof |
Operation environment : | Environment temperature +5°C+40° |
Atmospheric pressure:86-106kPa | |
Σχετική υγρασία:20%~90% | |
OR | |
περιβάλλον :Environment temperature -22°C-55°C | |
Atmospheric pressure:50~106kPa | |
Σχετική υγρασία:90% | |
Electrical Safety: | In accord with the stipulation of EC 60601-1:1998And EN 60601-1 |
Χαρακτηριστικά: | |
Hard based free-flow protection: | When the door open ,it effectively prevents any free-flow .Prevent any danger to the patients. |
Drop detector: | |
It’s used to calculate the drop infused for the patients, Meanwhile it automatically adjust the accuracy by itself. According to the current infusion set. One of another, the detector can also detect the abnormal flow rate and sends this information to the CPU, The CPU sends instruction to control the peristalsis pieces, accordingly make the accurate infusion come true. | |
Νυχτερινή λειτουργία: | |
At night, in order to ensure the patients have a good rest, this pump has the silence function and screen-protection mode. |
Συσκευασία & Αποστολή
Στοιχεία της εταιρείας
Οι Υπηρεσίες μας
Επιπλέον πληροφορίες
Τύπος: | Infusion Pump with Auto Caliration |
---|---|
Μάρκα: | THR |
Αριθμός μοντέλου: | THR-IP100 |
Τόπο καταγωγής: | Jiangsu, Κίνα |
Ταξινόμηση οργάνων: | Class I |
Εγγύηση: | 1 Ετος |
Εξυπηρέτηση μετά την πώληση: | Ηλεκτρονική τεχνική υποστήριξη |
Ονομασία προϊόντος: | Caliration Infusion Pump |
AC power supply: | ΜΕΤΑ ΧΡΙΣΤΟΝ 100 to 240V±10%,50/60Hz; |
MOQ: | 1 unit |
Πιστοποιητικό: | CE ISO |
OEM: | Διαθέσιμος |