APM801 ethernet modbus tcp / rtu power quality analysis 3 phase energy monitor meter

Descrizione

APM801 ethernet modbus tcp / rtu power quality analysis 3 phase energy monitor meter

Descrizione del prodotto

APM801 ethernet modbus tcp / rtu power quality analysis 3 phase energy monitor meter

Dati tecnici

ModelloAPM801
Dimensione
Panel size96*96mm
Cut out92*92mm
Depth71mm
Dati tecnici
Ingresso Netthree-phase three-wire,three-phase four-wire
Frequenza45~65HZ
Voltaggiorated valueAC100V 110V 400V 690V
overload1.2times rated value(contineously);2times rated value/1second
power consumption<0.5VA(every channel)
Attualerated valueAC 1A,5UN,4mm2 wire can be connected
overload1.2times rated value(contineously);10times rated value/1second
power consumption<0.5VA(every channel)
Precisionevoltage current power consumption0.5S
active electrical energy0.5S
reactive electrical energy2S
harmonicclass 1
Digital inputdry contact input,inner power supply
Relay outputcontact type:main body normal open,module changeover contact; contact capacity:AC250V/3A DC30V/3A
Impulse outputoutput type optcoupler impulse
Analog outputDC 0~20mA,4~20mA,0~5V,1~5V
Analog inputDC 0~20mA,4~20mA,0~5V,1~5V
CommunicationRS485/Modbus-RTU communication and DLT645 protocol;
RS232/Profibus-DP protocol;
RJ45(Ethernet)/Modbus-TCP,http and DHCP protocol
Alimentazione elettricawork rangeAC85V~265VDC 100V~350V or AC100~415VDC 125V~500V
power consumption;main body power consumption≤15VA
Basic functions
three phase(I,U,kW,kvar,kWh,kvarh,Hz,cosφ),zero-sequence current In;
Four quadrant electric energy;real-time and max demand;last month and this month extreme value;
voltage unbanlanceness degree ;load current columnar display;
66 alarm types and external (SOE) each has 16 SOE,support SD card extend record;
2-63st harmonics;2DI+2DO RS485/Modbus;LCD display
Option auxiliary Function(can choose 3 functions at the same time)
1Multi-rate(F)
28DI+2DO(MD82)
3SD card(MLOG)
48AI+4AO(MA84)
5RS485(MCM)
6Ethernet(MCE)

Funzioni

Immagini dettagliate

Wiring

Contatto

FAQ

Informazioni aggiuntive

Luogo d'origine:

Shanghai, Cina

Marchio:

Acrel

Numero di modello:

APM801

Display Type:

Digital Only

Fase:

Three Phase, three phase

Measuring Energy Range:

0-999999.99 KWh

Accuracy Class:

0.5, 0.5

Tensione di uscita:

220v

temperatura di esercizio:

-20℃~+65℃

Dimensioni:

96*96mm, 96*96mm

Nome del prodotto:

3 phase monitoring meter

Schermo:

LCD

Frequenza:

45~65Hz

Input current:

AC 1A or 5A

Garanzia:

2 anni

Certificato:

CE

Communication:

Modbus RTU and TCP